Fixed tube sheet heat exchanger
The fixed tube sheet heat exchanger consists of tube box, shell, tube sheet, tube and other parts. It has a compact structure, more tubes, larger area under the same diameter, and simpler manufacturing.
- Commodity name: Fixed tube sheet heat exchanger
Classification:
Key words:
Product Details
- 产品描述
-
1. Overview
The structural characteristics of the fixed tube sheet heat exchanger are that a tube bundle is arranged in the shell, and the tubes are fixed to the tube sheet by welding or expansion at both ends of the tube bundle. The tube sheets at both ends are directly welded to the shell, the inlet and outlet pipes of the shell are directly welded to the shell, the outer circumference of the tube sheet and the head flange are fastened with bolts, and the inlet and outlet pipes of the tube pass are directly welded to the head. Several baffles are set in the tube bundle according to the length of the heat exchange tube. The tube pass of this heat exchanger can be divided into any number of passes by partitions.
2. Parameters
No.
Parameters
Unit
Description
1
Design flow rate
m³/h
Design flow rate of each fluid channel
2
Shell diameter
mm
Inner diameter of the shell
3
Tube outer diameter
mm
Outer diameter of the pipe
4
Tube inner diameter
mm
Inner diameter of the pipe
5
Number of tube passes
-
Number of pipes
6
Heat transfer area
m²
Total heat transfer area of the entire heat exchanger
7
Heat transfer coefficient(U)
W/m²·K
Total heat transfer coefficient (considering multiple factors such as wall surface and fluid)
8
Operating temperature
°C
Design operating temperature range of shell and tube fluids
3. The advantages of the fixed tube sheet heat exchanger
3.1. Small bypass seepage;
3.2. Fewer forgings are used and the cost is low;
3.3. No internal leakage;
3.4. The heat transfer area is 20% to 30% larger than that of the floating head heat exchanger.
4. The disadvantages of fixed tube sheet heat exchangers
4.1. The temperature difference between the shell and the tube wall is large. When t≥50℃, an expansion joint must be installed on the shell;
4.2 It is easy to generate temperature difference force, and the tube sheet and the tube head are prone to temperature difference stress and damage;
4.3. The shell side cannot be mechanically cleaned;
4.4. After the tube corrodes, it is scrapped together with the shell, and the equipment life is short.
5. Schematic diagram