High voltage electrode steam boiler
The electrodes are immersed in water with a certain conductivity. When electricity is applied, the conductivity of the water generates current, which generates heat and turns the water into high-temperature water or steam. This water can be stored through a heat exchange device outside the boiler or directly supplied to users.
- Commodity name: High voltage electrode steam boiler
Classification:
Key words:
Product Details
- 产品描述
-
1.Working Principle
- The submerged double-barrel high-voltage electrode steam boiler consists of an inner cylinder and an outer cylinder, the outer cylinder is directly grounded, and the inner cylinder is isolated from the outer cylinder by insulating material.
- The three phase electrodes are arranged symmetrically in the inner cylinder to form zero potential and no neutral line is required. An electric current passes through a three-phase electrode to water with a set conductivity to convert electrical energy into heat energy, resulting in saturated steam that can be controlled and utilized.
- The amount of boiler evaporation is controlled by the water level of the inner cylinder and the conductivity of the water.
- Power Range4.3t/h-85.7t/h。
- Working pressure≤2.5MPa。
- Application scenarios: industrial steam supply, power plant start-up boiler
2.Performance Parameter
Type
LDJ-4.3
LDJ-14.3
LDJ-21.4
LDJ-28.6
LDJ-35.7
LDJ-42.8
LDJ-57.0
Steam(t/h)
≤4.3
5.0-14.3
15.0-21.4
22.8-28.6
30.0-35.7
37.1-42.8
44.3-57.0
Power(MW)
≤3
4-10
11-15
16-20
21-25
26-30
31-40
Diameter(mm)
1600
2000
2200
2400
2600
2800
3200
Altitude(mm)
4200
5600
6400
6700
7000
7500
8300
Steam outlet size
DN100
DN150
DN200
DN250
DN250
DN300
DN350
Inlet size
DN40
DN40
DN50
DN65
DN80
DN80
DN100
Hauled weight(kg)
2600
6000
8000
11000
15000
18500
22000
Operating Weight(kg)
6600
12400
14000
20000
30000
37000
44000
Main pressure element material
Q345R
Working Pressure(MPa)
≤2.5(Saturated steam temperature 224℃)
Voltage
10kV
3.System Introduction
- The high voltage electrode steam boiler is composed of high voltage electrode steam boiler, feed water pump, internal circulation pump, automatic dosing device, water treatment device, deaerator, blowdown expansion vessel and control system.
- The feed pump and the inlet control valve jointly control the water intake of the boiler, balance the output steam, and maintain the stability of the total storage water of the boiler. The internal circulation pump, the central regulating valve and the power, pressure and level control point linkage adjustment, to maximize the steam demand.
- Load regulation range 0-100%, load fluctuation is less than 0.03MPa.
- Because the boiler evaporation area is large enough and the water separation device is set, it can provide high quality steam with a dryness greater than 99.8%.